Whole-Body CT in Multiple Trauma Patients: Clinically Adapted Usage of Differently Weighted CT Protocols
Stefan Ulrich Reske1,2, Rainer Braunschweig1,3, Andreas Wolfgang Reske4
1Department of Diagnostic Imaging and Interventional Radiology, BG-Klinikum Bergmannstrost Halle, Halle (Saale), Germany.
Purpose:
Whole-body CT (wbCT) has been established as an internationally accepted diagnostic modality in multiple trauma. Until 2011, a uniform CT scanning protocol was used for all multiple trauma patients (pat.) at our hospital (OLD protocol = OP). In 2011, 2 new differently weighted protocols were introduced: TIME protocol (TP) for hemodynamically unstable pat. and DOSE protocol (DP) for pat. with stable vital parameters. The aim of this study was to compare the original "One-fits-all-concept" with the new, clinically oriented approach to wbCT.
Materials And Methods:
This study retrospectively evaluated 3 distinct wbCT protocols, looking at automatic exposure control variation (AEC; OP/TP) and arm positioning close to the body/overhead (TP/DP). The analysis included waist circumference (WC, cm), injury severity score (ISS), examination time (ET, min), image noise (IN), and effective dose (E, mSv). Normality of distribution was assessed with the Kolmogorov-Smirnov test. Data are given as median and range. Test of significance with Kruskal-Wallis test or Mann-Whitney-U-test. Level of significance: 0.05.
Results:
308 pat. were included in the study (77 % m; age: 46 a, 18 - 90 a; WC: 93 cm, 66 - 145 cm). ISS was 14 (OP; n = 104; 0 - 75), 18 (TP; n = 102; 0 - 75) and 9 (DP; n = 102; 0 - 50). ET was 3.9 min (OP; 3.3 - 5.6 min), 4.1 min (TP; 2.8 - 7.2 min) and 7.7 min (DP; 6 - 10 min). IN showed no significant differences when comparing OP/TP but was significantly reduced in DP. For a wbCT (vertex to ischium), E could be reduced from 49.7 mSv to 35.4 mSv by optimizing AEC (OP/TP). Through the overhead repositioning of the arms in DP, a further reduction to 28.2 mSv was achieved.
Conclusion:
AEC and arm repositioning have a crucial influence on image quality and dose. The presented clinical approach is superior to the original concept.
Key Points:
· The use of 2 differently weighted wbCT protocols allows a more flexible approach to the patient's clinical presentation.. · The clinically adapted concept presented in this study allows trauma care centers to reduce the collective dose.. · Whole-body CT is leading to exposure to relevant radiation doses - further multicenter research is required..
Citation Format:
· Reske SU, Braunschweig R, Reske AW et al. Whole-Body CT in Multiple Trauma Patients: Clinically Adapted Usage of Differently Weighted CT Protocols. Fortschr Röntgenstr 2018; 190: 1141 - 1151.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Atomic Weight