Assessment of Sensory Thresholds in Dogs Using Mechanical and Hot Thermal Quantitative Sensory Testing
Published on: October 26, 2021
Feasibility and reliability of electrical, mechanical and thermal nociceptive testing and assessment of diffuse
Hélène Lm Ruel1,2, Ryota Watanabe1,2, Marina C Evangelista1,2
1Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, QC, Canada, helene.ruel.2@umontreal.ca.
Purpose:
Quantitative sensory testing has been used to assess the somatosensory system. This study aimed to evaluate the feasibility and reliability of electrical (ENT), mechanical (MNT) and thermal (TNT) nociceptive testing and the effect of a conditioning stimulus on MNT.
Patients And Methods:
Sixteen healthy client-owned dogs were included in this study. Stimulation was applied bilaterally to the dorsal and plantar aspect of the metacarpus and metatarsus respectively, using transcutaneous electrical stimulator, algometry and a cold nociceptive device in a randomized order until a behavior response was observed or a cut-off reached. Tests were performed twice (60 seconds apart) by two observers. Retesting was performed 5 hours later. The diffuse noxious inhibitory control was tested by comparing MNT pre- and post-conditioning stimuli. Sham-testing was performed for ENT and TNT. Statistical analysis included linear model and intra-class correlation coefficient (P<0.05).
Results:
Feasibility was 99% (ENT), 93.5% (MNT) and 93.6% (TNT). Data for TNT were not analyzed due to inconsistent results. Mean ± SD were 48±22.6 mA (ENT) and 11.9±3.5 N (MNT). MNT was higher for thoracic than for pelvic limbs (P=0.002). Conditioning stimulus increased MNT (P=0.049). Inter-observer reliability was 91.4% (ENT) and 60.9% (MNT). False-positive responses were 15% (ENT) and 35.7% (TNT).
Conclusion:
ENT was feasible, repeatable and superior to MNT and TNT. The assessment of the diffuse noxious inhibitory control with a conditioning stimulus showed promising results in dogs. These tools could be used in naturally-occurring disease to provide insight on their underlying mechanisms and therapeutics.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Diffusion
Diffusion
Nociception
Reliability and Validity
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...