Related Experiment Video
Updated: Feb 2, 2026

Automated Detection and Analysis of Exocytosis
Published on: September 11, 2021
Automated monitoring system for events detection in sewer network by distribution temperature sensing data
Abdelhak Kessili1, Jes Vollertsen2, Asbjørn Haaning Nielsen2
1Department of Civil Engineering and Hydraulics, Faculty of Science and Technology, University of Jijel, Ouled Aissa 18000, Jijel, Algeria
Abstract:
This study is related to distribution temperature sensing (DTS) in sewers for tracing illicit or unintended inflows to foul sewers. A DTS measurement is performed with a fiber optic cable that is installed at the invert of a sewer pipe in combination with a standalone laser/computer instrument. This set-up generates in-sewer temperature measurements with high resolutions in time (every minute) and space (every metre) along the cable over long periods of time (weeks on end). The prolonged monitoring period in combination with the high level of detail in the dataset allows the study of anomalies (i.e., unexpected temperatures and/or temperature variations at certain locations), even if these only occur very infrequently. The objective of this paper is to develop an automated tool to analyze the large data masses and identify anomalies caused by illicit or unintended inflows. In this study, an algorithm for detecting the temperature changes that are caused by both wastewater discharge and inflow of stormwater are developed. A comparison of the results of the automated procedure to the results of a manual assessment of the datasets (Elmehaven, Denmark) shows that the automated procedure performs very well.
Related Concept Videos
Distribution Reliability and Automation
Data: Types and Distribution
Distributions in...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...