Related Experiment Video
Updated: Feb 2, 2026

An Improved Method for Collection of Cerebrospinal Fluid from Anesthetized Mice
Published on: March 19, 2018
Effect of sample processing and time delay on cell count and chemistry tests in cerebrospinal fluid collected from
Ana Mlinarić1, Željka Vogrinc1, Zrinka Drenšek2
1Department of Laboratory Diagnostics, University Hospital Centre Zagreb, Zagreb, Croatia.
Introduction:
Cerebrospinal fluid (CSF) from extra-ventricular drainage (EVD) systems is routinely analysed to diagnose EVD-related bacterial meningitis. We investigated the effect of time delay and sample processing on cell count and basic biochemistry results in EVD CSF to define optimal turnaround time and whether manual and automated cell counting are comparable in such samples.
Materials And Methods:
In total, 32 EVD CSF samples were analysed. Baseline testing included cell counting (Fuchs-Rosenthal chamber and Sysmex XE5000) and biochemistry analyses (glucose, lactate, proteins). Manual cell counting was also performed at intervals of 61-90 and 91-150 minutes from baseline in the residual sample. Biochemistry analyses were performed in samples before and after centrifugation at baseline and at 91-150 minutes interval.
Results:
At 91-150 minutes total cell count (P < 0.001), large lymphocytes (P = 0.007), neutrophils (P < 0.001) and phagocytes (P = 0.006) obtained by manual counting decreased and the number of disintegrated cells count increased (P = 0.016) compared to the baseline values. Considering method comparison, proportional difference between methods for all cell (sub)groups was obtained, whereas polymorphonuclears also showed the constant difference (y = 11.21 + 1.22x). Compared to centrifuged CSF, lower concentration of glucose and lactates were obtained in uncentrifuged samples (P < 0.001) at baseline.
Conclusions:
Manual cell counting should be performed within 60 minutes as any delay can alter results. The same counting technique should be used to obtain longitudinally assessable results. Biochemistry tests are stable in uncentrifuged CSF up to 2.5 hours.
Related Concept Videos
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
Chemistry of the Cell
Water
The polarity of the water molecule and its resulting hydrogen bonding makes water a unique substance with special properties that are intimately tied to the processes of life. Life originally evolved in an aqueous environment, and most of an organism’s cellular chemistry and metabolism occur inside the aqueous contents of the cell’s cytoplasm. Special properties of water are its high heat capacity...
Chemistry of the Cell
Cyclic Processes And Isolated Systems
In the case of a non-isolated system, the change in the internal energy is zero only if the process is cyclic. A thermodynamic process is considered cyclic if the system undergoes a series of changes and returns to its initial state.
Consider a cyclic process that returns to its initial state, undergoing a four-step process. The heat transfer along each...
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Gas Chromatography: Sample Injection Systems