Cardiorespiratory effects of variable pressure thoracic insufflation in cats undergoing video-assisted thoracic
Philipp D Mayhew1, Peter J Pascoe1, Michelle A Giuffrida1
1Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, California.
Objective:
To evaluate the effects of intrathoracic insufflation on cardiorespiratory variables and working space in cats undergoing video-assisted thoracic surgery.
Study Design:
Prospective randomized study.
Animals:
Six healthy cats.
Methods:
Cats were anesthetized using a standardized protocol. A Swan-Ganz catheter was positioned in the pulmonary artery under fluoroscopic guidance for measurement of cardiac output. Intrathoracic pressures (ITP) of 0 (baseline), 3, and 5 mm Hg were induced with CO2 and maintained for 30 minutes. Statistical comparison of cardiorespiratory variables was performed. After the procedures, all cats were recovered from anesthesia. Videos of thoracic working space at each ITP level were scored in a blinded fashion by 3 board-certified surgeons using a numerical scale from 0-10.
Results:
All cats tolerated insufflation with 3 and 5 mm Hg for 30 minutes without oxygen desaturation, although ventilatory levels had to be increased substantially to maintain eucapnia and oxygenation. Cardiac index was not significantly different from baseline after 30 minutes at 3 mm Hg but was significantly lower after 30 minutes at 5 mm Hg compared with 3 mm Hg. Oxygen delivery was unaffected by 3 or 5 mm Hg compared with baseline. Scores for working space increased between baseline and 3 and 5 mm Hg but were not different between 3 and 5 mm Hg.
Conclusion:
CO2 insufflation to 5 mm Hg seems well tolerated in healthy cats, provided ventilatory settings are substantially increased as ITP increases.
Clinical Significance:
Thoracic CO2 insufflation of 3 mm Hg in cats during video-assisted thoracic surgery is associated with less hemodynamic perturbation than 5 mm Hg insufflation and may provide the benefit of improved working space compared with baseline.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Thoracic Aorta
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...