A method to correct background phase offset for phase-contrast MRI in the presence of steady flow and spatial
Aaron A Pruitt1, Ning Jin2, Yingmin Liu3
1Biomedical Engineering, Ohio State University, Columbus, Ohio.
Purpose:
Background phase offsets in phase-contrast MRI are often corrected using polynomial regression; however, correction performance degrades when temporally invariant outliers such as steady flow or spatial wrap-around artifact are present. We describe and validate an iterative method called automatic rejection of temporally invariant outliers (ARTO), which excludes these outliers from the fitting process.
Methods:
The ARTO method iteratively removes pixels with large polynomial regression errors analyzed by a Gaussian mixture model fitting of the residual distribution. A total of 150 trials of a simulated phantom (75 with wrap-around artifact) and 125 phase-contrast MRI cines from 22 healthy subjects (48 with wrap-around artifact) were used for validation. Background phase offsets were corrected using second-order weighted regularized least squares (WRLS) with and without ARTO. Flow volumes after WRLS and WRLS+ARTO corrections were compared with the known truth (phantom) and stationary phantom reference (in vivo) using Bland-Altman analysis. The ratio between the pulmonary flow and the systemic flow was also computed in a subset of 6 subjects.
Results:
In the simulated phantom, compared with WRLS and no correction, correction with WRLS+ARTO produced superior agreement in volumetric flow quantification with the known truth. In vivo, WRLS+ARTO also produced superior agreement with stationary phantom-corrected volumetric flow compared with WRLS and no correction. In data sets with wrap-around artifact, WRLS produced significantly larger variance in the pulmonary flow and systemic flow ratio than stationary phantom correction (P = .0008).
Conclusion:
The proposed method provides automatic exclusion of temporally invariant outliers and produces flow quantification results comparable to stationary phantom correction.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Phase Transitions
Phase Diagrams
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...