Enhanced Frequency Difference of Tumor inside Vibrated Tissue by a Compression Cylinder
Abstract:
Breast cancer diagnosis has been mostly accomplished by imaging technologies. These methods have the great advantages of detecting the presence and location of breast cancer. However, it's difficult to distinguish between a benign and malignant tumor in a deep position because both tumor types look similar. In this paper, we vibrated the tissue including tumor from skin with a compression cylinder to analyze the frequency difference for distinguishing the tissue type. Before distinguishing a benign and malignant tumor, it's necessary to validate to distinguish between normal tissue and tumor. The objective is to validate the feasibility of using a compression cylinder that emphasizes the differences in frequency between normal tissue and tumor. In two experiments, we measured the displacement on the surface of a breast phantom vibrated by an impulse hammer. We compared the frequency difference with and without a cylinder. We also studied the frequency changes in the relationship between tumor and cylinder position. We found a 5.0 Hz difference in compliance between normal tissue and the simulated tumor using a compression cylinder. The difference in frequency correlated negatively with distance from the simulated tumor to a compression cylinder. We concluded that a compression cylinder would enhance the frequency difference between normal tissue and a simulated tumor with appropriate configuration.
More Related Videos
08:49Author Spotlight: Unveiling the Potential of VSFG Microscopy in Studying Mesoscopically Heterogeneous Self-Assembled Structures
Published on: December 1, 2023
09:43Interfacial Molecular-level Structures of Polymers and Biomacromolecules Revealed via Sum Frequency Generation Vibrational Spectroscopy
Published on: August 13, 2019
Related Concept Videos
Vibrating Concrete
Frequency-dependent Selection
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...