Related Experiment Video
Updated: Feb 2, 2026

Assessing Burrowing, Nest Construction, and Hoarding in Mice
Published on: January 5, 2012
Unobtrusive Heartbeat Detection from Mice Using Sensors Embedded in the Nest
Abstract:
Unobtrusive monitoring of physio-behavioral variables from animals can minimize variability in preclinical research and thereby maximize the potential for clinical translation. In this paper, we present the design, implementation, and validation of an instrumented nest providing continuous recordings of seismocardiogram (SCG) signals and skin temperature. SCG represents the chest-wall vibrations associated with the heartbeat, and can potentially provide a measure by which individual heartbeats can be detected without the need for electrodes or implantable devices. A non-contact electric field sensor placed in proximity to the animal in the nest was also used to detect respiratory dynamics. The setup was tested with a total of six anesthetized mice. To understand the effects of mouse positioning within the nest on signal quality, the error in heartbeat detection at different positions of the sensor on the body was quantified, with a simultaneously-obtained electrocardiogram (ECG) as the reference standard. At the optimal placement determined with this approach, multiple perturbations were performed such as pinching, changing ambient temperature, and norepinephrine injection to modulate physiology and assess measurement capability. Heartbeat intervals obtained from the ECG and SCG during the perturbations were correlated (R2=0.82) and were in agreement according to Bland-Altman methods (bias: 0.006ms, 95% confidence interval: [-3.79, 3.78]ms) suggesting that SCG can be reliably used for unobtrusive heartbeat detection. Accordingly, the setup can provide a means by which individual heartbeats - and thereby heart rate and heart rate variability indices - can be quantified without the need for any sensors to be attached to the body of the animal.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

