Related Experiment Video
Updated: Feb 2, 2026

Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand
Published on: May 20, 2020
Flexo-glove: A 3D Printed Soft Exoskeleton Robotic Glove for Impaired Hand Rehabilitation and Assistance
Abstract:
This paper presents a compact and streamlined design of a soft exoskeleton glove for assistance in activities of daily livings and also rehabilitation purposes of patients with hand function impairment. Most of the existing hand exoskeletons have focused on either providing a customizable and modular design or making it portable to be used outside the hospital environment. We have developed a design of an exoskeleton glove that combines both of these features in one compact design. This was achieved by using a parameterised CAD design of glove, 3D printing of soft (i.e., compliant) materials, design a bidirectional cable driven spooling system and integrating them together in a modular fashion. The overall weight of the Flexo-glove is 330g including battery and is able to provide 22N pinch force, 48N power grasp force and object grasp size of up to 81mm in diameter. The device has two control modes: intention-sensing via wireless sEMG for assistive mode and externally-directed via an accompanying smartphone application for rehabilitation (repetitive exercise) programs, both managed through Bluetooth communication. The effectiveness of the proposed design is evaluated in performing cylindrical, hook, and pinch grasps on various objects.
More Related Videos
05:30Soft Pneumatic Robot Modulates Graph Theory Metrics of Brain Network for Hand Rehabilitation After Stroke
Published on: October 10, 2025
06:00A Rehabilitation Program of Exoskeleton-assisted Body Weight-Supported Treadmill Training with Non-immersive Virtual Reality for Stroke Patients
Published on: May 16, 2025
Related Concept Videos
Hand hygiene
Hand washing...
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Effect of Hepatic Disease on Pharmacokinetics: Dose Adjustments Due to Hepatic Impairment
Matrix-Assisted Laser Desorption Ionization (MALDI)