Related Experiment Video
Updated: Feb 2, 2026

Acquisition and Semi-Automated Analysis of Respiratory Muscle Surface Electromyography
Published on: January 24, 2025
Identifying Noisy Electrodes in High Density Surface Electromyography Recordings Through Analysis of Spatial
Abstract:
In this study we developed a technique for identifying noisy electrodes in high density surface electromyography (HD-sEMG). The technique finds the spatial similarity of each electrode in the electrode array by counting the number of interactions the electrode has. Using this information the technique identifies noisy electrodes by finding electrodes that are significantly dissimilar to the other electrodes. The HD-sEMG recordings used in this study were taken from three participants who performed two isometric contractions of their biceps at 40% and 80% of their maximum voluntary contraction (MVC) force. White Gaussian noisy was added to a varying number of recorded signals before being digital filtering to generate a variety of recordings to test the technique with. In the recordings, groups of 2, 4, 8, and 16 electrodes had noise added such that the signal to noise ratios (SNR) were 0, 5, 10, 15, and 20dB. The results show that the technique can reliably identify groups of 2, 4, and 8 noisy electrodes with SNRs of 0, 5, and 10dB.
Related Concept Videos
Causes of Similarity-Dissimilarity Effect
Factors Influencing Attraction III: Similarity
Standard Electrode Potentials
Density
Current Density
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...