Capacitive Micromachined Ultrasonic Transducer (CMUT) ring array for transcranial ultrasound neuromodulation
Abstract:
Non-invasive brain stimulation of small animals plays an important role in neuroscience especially in understanding fundamental mechanisms of brain disorders. Here, we report a miniaturized ultrasound transducer array designed for non-invasive brain stimulation of mouse for the first time. We designed and fabricated a Capacitive Micromachined Ultrasonic Transducer (CMUT) ring array that operates at 183 kHz in immersion. The fabricated transducer ring array exhibited a focal length of 2.25 mm and a maximum intensity of 175 mW/cm2. Because the array was fabricated in a ring shape, a natural focus was achieved and thus, no additional focusing circuitries or acoustic lens were required. Thus, a compact packaging was achieved with minimum surgical procedures for in vivo mouse experiments. Using the developed micromachined transducer array and simple packaging, we successfully induced the motor responses of a mouse. The success rate of ultrasound stimulation was quantified by recording the electromyography (EMG) signal during the stimulation. While the current ultrasound neuromodulation system is limited to acute experiments, the presented light (< 1 g) and compact ultrasound neuromodulation system with a natural focus would enable chronic ultrasound neuromodulation experiments on freely-moving mice.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
04:00Focused Ultrasound Neuromodulation of Human In Vitro Neural Cultures in Multi-Well Microelectrode Arrays
Published on: May 3, 2024
Related Concept Videos
Equivalent Capacitance
Equivalent Capacitance
The following strategies are adopted to calculate...
Capacitors and Capacitance
When the conductors are two identical parallel plates, it is called a parallel plate capacitor. When battery terminals are...
Design Example: Capacitance Multiplier Circuit
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):