Related Experiment Video
Updated: Feb 2, 2026

Microfluidic Production of Lysolipid-Containing Temperature-Sensitive Liposomes
Published on: March 3, 2020
In vitro Measurement of Release Kinetics of Temperature Sensitive Liposomes with a Fluorescence Imaging System
Abstract:
Temperature sensitive liposomes (TSL) are a promising type of nanoparticles for localized drug delivery. TSL typically release the contained drug at mild hyperthermic temperatures (40-42 °C). Combined with localized hyperthermia, this allows for local drug delivery. In vitro characterization of TSL involves measurements of drug release at varying temperatures, but current methods are inadequate due to low temporal resolution of ~8 - 10 seconds. We present a novel method for measuring the drug release with sub-second temporal resolution. In the proposed system, the TSL entrapping the fluorescent drug (Doxorubicin) are pumped through a capillary tube. The tube is rapidly heated to a desired temperature via Peltier element. Since fluorescence increases as drug is released from TSL, drug release kinetics can be measured via fluorescent imaging. By fitting exponential models, we calculated the time constants of drug release at temperatures of 39.5, 40.5 and 41.5.C were about 6.09, 2.06 and 1.03 seconds, respectively. Our initial tests show that the developed system can measure TSL release at subsecond resolution, and thus allow adequate in vitro evaluation of TSL formulations.
More Related Videos
10:55Fluorescence-quenching of a Liposomal-encapsulated Near-infrared Fluorophore as a Tool for In Vivo Optical Imaging
Published on: January 5, 2015
07:47Custom-designed Laser-based Heating Apparatus for Triggered Release of Cisplatin from Thermosensitive Liposomes with Magnetic Resonance Image Guidance
Published on: December 13, 2015
Related Concept Videos
Kinetic Molecular Theory: Molecular Velocities, Temperature, and Kinetic Energy
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...
Kinetic Energy
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...