Related Experiment Video
Updated: Feb 2, 2026

The Intra-Aortic Balloon Pump
Published on: February 5, 2021
Hemodynamic Evaluation of an Intra-Atrial Blood Pump on a Pulsatile Mock Circulatory Loop
Abstract:
An intra-atrial pump (IAP) was proposed that would be affixed to the atrial septum to support the compromised left ventricle (LV) without harming the ventricular tissue in patients with early-stage heart failure. The IAP is designed to operate in parallel with the LV, drawing blood from the left atrium and unloading the LV. In previous hydraulic studies, different blade geometries were tested for the IAP; however, it is important to know how the blade geometry affects the IAP's hemodynamic performance in the human cardiovascular system. In this study, a mock circulatory loop (MCL) with physiological response was used to evaluate the hemodynamic effects of IAP blade geometry and connection configuration in the human cardiovascular system. In a $2 \times 2$ study, two different blade geometries (with steep vs flat pressure/flow curves) were tested in two different connection configurations: the proposed configuration (left atrium to aorta) and the conventional configuration for LVADs (LV to aorta). We found that atrial cannulation is feasible and creates a beneficial hemodynamic environment, although it is inferior to the one created by ventricular cannulation. The steepgradient pump performed better than the flat-gradient pump in atrial insertion.
Related Concept Videos
Anatomy of the Circulatory System
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...

