Accurate imaging is key for Left Atrial Appendage (LAA) occlusion. Real-time 3D transesophageal echocardiography offers superior accuracy for LAA assessment compared to 2D methods, without radiation or contrast.
Area of Science:
- Cardiology
- Medical Imaging
- Interventional Procedures
Background:
- Percutaneous Left Atrial Appendage (LAA) transcatheter occlusion requires precise imaging for procedural success.
- Accurate LAA dimensions are critical to avoid complications like device changes and prolonged procedures.
- Various imaging modalities, including CT, MRI, and ultrasound, are used for assessment.
Purpose of the Study:
- To evaluate the accuracy of commonly used imaging modalities for pre-procedural LAA assessment in transcatheter occlusion.
- To compare the diagnostic performance of different imaging techniques for LAA morphology.
Main Methods:
- A literature review was conducted using PubMed, retrieving 32 articles.
- The study analyzed the accuracy of 2D transesophageal echocardiography, 3D transesophageal echocardiography, CT, and 3D printing for LAA assessment.
- Institutional Review Board (IRB) approval was waived due to reliance on published data.
Main Results:
- Real-time 3D transesophageal echocardiography demonstrates higher accuracy than 2D transesophageal echocardiography for LAA measurements.
- 3D computed tomography, especially when combined with 3D printing, shows exceptional accuracy.
- 3D transesophageal echocardiography provides accurate measurements without radiation or contrast administration.
Conclusions:
- Real-time 3D transesophageal echocardiography is a highly accurate imaging modality for LAA assessment.
- 3D CT with 3D printing offers excellent accuracy, while 3D TEE is preferred for its safety profile.
- An algorithmic approach to LAA assessment across procedural phases will be presented.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
101.2K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.
101.2K
Common Ion Effect
46.7K
Compared with pure water, the solubility of an ionic compound is less in aqueous solutions containing a common ion (one also produced by dissolution of the ionic compound). This is an example of a phenomenon known as the common ion effect, which is a consequence of the law of mass action that may be explained using Le Châtelier’s principle. Consider the dissolution of silver iodide:
46.7K
Improving Translational Accuracy
14.9K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.9K
Surface Appendages of Archaea
666
Archaeal surface appendages are highly specialized structures essential for environmental adaptation, encompassing roles in adhesion, biofilm formation, and motility. Among these appendages, pili and archaella stand out for their distinct morphologies and functionalities, enabling archaea to thrive in diverse and often extreme environments.Pili: Adhesion and Biofilm FormationPili are filamentous structures assembled from pilin protein subunits, primarily contributing to adhesion and biofilm...
666
Review and Preview
8.4K
In statistics, several tools are used to interpret the data. Measures of central tendency represent the characteristics of the data, such as mean, median, and mode. Additionally, measures of variance like standard deviation and range are used to find the spread of data from the mean. Relative standing measures the distance between data locations. Commonly used measures of relative standings are percentile, z score, and quartiles.
Percentiles are a type of fractile that partition data into...
Percentiles are a type of fractile that partition data into...
8.4K
Review and Preview
11.3K
Data are individual items of information obtained from a population or sample. Data may be classified as qualitative (categorical), quantitative continuous, or quantitative discrete. Because it is not practical to measure the entire population in a study, researchers use samples to represent the population. A random sample is a representative group from the population chosen by using a method that gives each individual in the population an equal chance of being included in the sample. Random...
11.3K