Myocardial Infarction and Functional Outcome Assessment in Pigs
Published on: April 25, 2014
Role of Iterative Reconstruction Algorithm for the Assessment of Myocardial Infarction with Dual Energy Computed
Gaston A Rodriguez-Granillo1, Alejandro Deviggiano1, Carlos Capunay1
1Department of Cardiovascular Imaging, Diagnóstico Maipú, Av Maipú 1668, Vicente López (B1602ABQ) Buenos Aires, Argentina.
Rationale And Objectives:
Low monochromatic energy levels (40 keV) derived from delayed enhancement dual energy cardiac computed tomography (DE-DECT) allow the evaluation of myocardial infarcts (MI) among stable patients, although at the expense of high image noise. We explored whether the application of adaptive statistical iterative reconstruction (ASIR) to 40-keV DE-DECT (unavailable with previous software versions) might improve image quality and detection of MI in stable patients.
Materials And Methods:
We prospectively enrolled patients with a history of previous MI, and performed delayed-enhancement cardiac magnetic resonance (DE-CMR) and DE-DECT within the same week. DE-DECT images were reconstructed with 0% and 60% ASIR.
Results:
MI was identified in 18 (80%) patients with both DE-CMR and DE-DECT. On a per segment basis, we did not identify significant differences regarding the diagnostic performance of DE-DECT with and without ASIR [area under receiver operating characteristic curve 0.86 vs. 0.83, p = 0.10]. The application of ASIR improved the signal-to-noise ratio of DE-DECT with 0% ASIR compared to DE-DECT with 60% ASIR (6.07 ± 2.1 vs. 11.1 ± 4.5, p < 0.0001). However, qualitative assessment of MI image quality (3.35 ± 1.2, vs. 3.55 ± 1.1, p = 0.10) and diagnostic confidence (4.40 ± 0.9 vs. 4.60 ± 0.8, p = 0.10) were not significantly improved. Using DE-DECT with 60% ASIR, a threshold over 199 HU showed a sensitivity of 67% and a specificity of 92% for the detection of segments with MI.
Conclusion:
In this study, DE-DECT allowed accurate detection of MI among stable patients compared with DE-CMR, and the application of ASIR improved signal-to-noise ratio of DE-DECT, although the diagnostic performance showed only non-significant improvements.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
What is Energy?
Role of Communication in the Nursing Process I: Assessment and Diagnosis
The nursing process considers the patient's emotional and physical well-being. The process can be repeated or stopped at any point if judged essential. Assessment is the first step in the nursing...