Related Experiment Video
Updated: Feb 2, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Expiratory reactance abnormalities in patients with expiratory dynamic airway collapse: a new application of impulse
David I Fielding1, Justin Travers2, Phan Nguyen3
1Dept of Thoracic Medicine, Royal Brisbane and Women's Hospital, Herston, Australia.
Abstract:
Expiratory dynamic airways collapse (EDAC) is a condition that affects the central airways; it is not well characterised physiologically, with relatively few studies. We sought to characterise impulse oscillometry (IOS) features of EDAC in patients with normal spirometry. Expiratory data were hypothesised to be the most revealing. In addition, we compared IOS findings in chronic obstructive pulmonary disease (COPD) patients with and without EDAC. EDAC was identified at bronchoscopy as 75-100% expiratory closure at the carina or bilateral main bronchi. Four patient groups were compared: controls with no EDAC and normal lung function; lone EDAC with normal lung function; COPD-only patients; and COPD patients with EDAC. 38 patients were studied. Mean IOS data z-scores for EDAC compared to controls showed significantly higher reactance (X) values including X at 5 Hz, resonance frequency and area under the reactance curve (AX). EDAC showed significantly greater expiratory/inspiratory differences in all IOS data compared to controls. Stepwise logistic regression showed that resonant frequency best discriminated between EDAC and normal control, whereas classification and regression tree analysis found AX ≥3.523 to be highly predictive for EDAC in cases with normal lung function (14 out of 15 cases, and none out of eight controls). These data show a new utility of IOS: detecting EDAC in patients with normal lung function.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Related Concept Videos
Impulse
Additionally, it can be shown that the...
Abnormal Proliferation
Impulse Response
Kirchhoff's law forms an input signal equation, with the capacitor's current and voltage providing the output. Substituting the current and dividing by RC yields a differential equation. The output for an impulse input is the impulse...
Dynamics Of Circular Motion: Applications
Principle of Impulse and Moment
Impulse-Momentum Theorem
By writing Newton's second law of motion in terms of the momentum of an object and the external force acting on it, and simultaneously using the definition of the impulse vector, it can be shown that the total impulse on an object is equal to its...