3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
A novel soft tissue thickness measuring method using cone beam computed tomography
Önder Gürlek1, Şule Sönmez1, Pelin Güneri2
1Department of Periodontology, School of Dentistry, Ege University, Izmir, Turkey.
Objective:
The aim of this study was to introduce a novel soft tissue thickness measurement method using cone beam computed tomography (CBCT) and to compare the new method with ultrasonic device applications and transgingival probing measurements.
Methods:
Twenty-five participants (12 female, 13 male, age range, 25-51 years) were included the study. Soft tissue thickness in lateral incisor, canine, premolar, and molar regions were measured using transgingival probing (group T), ultrasonic device (group U), and CBCT scan measurements (group C). Differences and correlations between groups and agreement between measurement methods were evaluated.
Results:
Soft tissue thickness was significantly lower in group U in premolar region, but was significantly higher in molar region compared with group C and group T (P < .05). There were significant positive correlations in lateral incisor and canine region, between group U and group C, in premolar region between group T and group C, and in molar region between group U and group C, and between group C and group T (P < .05). The highest agreement between measurement methods was evident between group T and group C.
Conclusion:
Soft tissue thickness values in maxilla may differ depending on the measurement method and location of the measurement. Ultrasonic device, transgingival probing, and CBCT measures may not necessarily correlate in all locations. The high agreement between CBCT measurements and transgingival probing may suggest the newly introduced method as a promising technique for soft tissue thickness evaluation.
Clinical Significance:
This study evaluated the relation between different soft tissue thickness measurement methods and demonstrated a novel method which can be used in any part of the mouth. The outcome also suggested that the measurement method and the location might affect the soft tissue thickness value obtained, and therefore might be important in clinical decision making.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Area Computation by the Alternative Coordinate Method
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving