Related Experiment Video
Updated: Feb 2, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Complete Sternal-Sparing HeartMate 3 Implantation: A Case Series of 10 Consecutive Patients
Katherine L Wood1, Brian C Ayers1, Fabio Sagebin1
1Division of Cardiac Surgery, University of Rochester Medical Center, Rochester, New York.
Background:
Left ventricular assist device (LVAD) therapy has been the standard of care for selected patients with advance heart failure. Even though considerable strides have been achieved with the introduction of the newest centrifugal pump, therapy is still burdened with significant perioperative complications. Smaller devices, along with improved techniques and instruments, have encouraged the adoption of minimally invasive cardiac surgery (MICS) techniques for LVAD implantation to improve perioperative outcomes.
Methods:
We describe a technique for complete sternal-sparing (CSS) HeartMate 3 (Abbott Laboratories, Abbott Park, IL) left ventricular assist device (LVAD) implantation using bilateral thoracotomies and discuss early clinical outcomes of the first ten consecutive patients who underwent CSS implantation of the HeartMate 3 LVAD at our institution.
Results:
The median length of stay in the intensive care unit was 3.5 days. No patients required reexploration for postoperative bleeding. There was no incidence of right ventricle failure, stroke, renal failure, hepatic failure, or myocardial infarction. The median length of hospitalization after LVAD implantation was 14.5 days (interquartile range, 12 to 17 days).
Conclusions:
Our early outcomes suggest that the CSS approach may reduce the incidence of right ventricular failure, bleeding, intubation time, and intensive care unit length of stay. Further studies are needed to fully elucidate the advantages of CSS LVAD implantation compared with median sternotomy.
Related Concept Videos
Spare Receptors
Resistors In Series
In a series circuit, the...
Series Resonance
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
Trigonometric Fourier series
The trigonometric Fourier series specifically expresses a periodic function with a defined period T using sine...
Convergence of Fourier Series
The Gibbs phenomenon refers to the persistent oscillations and overshoots that occur near discontinuities...

