Related Experiment Video
Updated: Aug 17, 2026

Trans-Tympanic Drug Delivery for the Treatment of Ototoxicity
Published on: March 16, 2018
Hypo- and hyperthermia in clinical auditory brain stem response measurement: two case reports
J W Hall1, J M Bull, L H Cronau
1Department of Otolaryngology-Head and Neck Surgery, University of Texas Medical School, Houston.
Abstract:
Two case reports are presented to highlight the important effects of body temperature in clinical auditory brain stem response (ABR) measurement. Case 1 is an 11 year old boy in coma secondary to severe head injury. High dose barbiturate therapy suppressed brain stem neurologic signs and the ABR was relied on as a monitor of CNS status. Hypothermia during this period of intensive care was a crucial factor for meaningful interpretation of ABR findings. The second case was a 26 year old male undergoing hyperthermic therapy for advanced cancer. As body temperature increased from 38 to 42 degrees Centigrade (107.6 degrees Fahrenheit), there was a systematic decrease in latency for waves III and V. An overall hyperthermia-related decrease in the wave I-V latency interval of 0.5 to 0.6 milliseconds was observed on two test dates. ABR results for these two cases are discussed in the context of basic knowledge on body temperature and auditory electrophysiology.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Homeostatic Imbalances in Body Temperature