Influence of the difference between implant body and screw materials on abutment screw loosening

Ryusuke Shinohara1, Kazuhiko Ueda2, Fumihiko Watanabe1,2

  • 1Functional Occlusal Treatment, Graduate School of Life Dentistry at Niigata, The Nippon Dental University.

Dental Materials Journal
|November 20, 2018
PubMed

Related Concept Videos

Screw: Problem Solving01:21

Screw: Problem Solving

In mechanical engineering, the interaction between a threaded screw shaft and a plate gear involves analyzing the resisting torque on the plate gear that can be overpowered when a specific torsional moment is applied to the shaft. To better comprehend this concept, consider a generic situation with a threaded screw shaft with a given mean radius and lead and a plate gear with a specified mean radius. The coefficient of static friction between the screw and gear is also provided.
To evaluate the...
701
Self-Locking Screw01:16

Self-Locking Screw

A square-threaded screw jack is a mechanical device widely used for lifting heavy loads or applying considerable force. One of the key features that can make a screw jack more effective and reliable is its self-locking capability.
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
2.5K
Frictional Forces on Screws01:17

Frictional Forces on Screws

Screws are characterized by a helical ridge known as a thread wrapped around a cylindrical shaft. They are commonly used as fasteners to hold objects together or to transmit power and motion in machines. One type of screw that is particularly useful for transmitting power is the square-threaded screw.
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
1.6K
Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.7K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.3K
Identifying Statistically Significant Differences: The F-Test01:14

Identifying Statistically Significant Differences: The F-Test

The F-test is used to compare two sample variances to each other or compare the sample variance to the population variance. It is used to decide whether an indeterminate error can explain the difference in their values. The underlying assumptions that allow the use of the F-test include the data set or sets are normally distributed, and the data sets are independent of each other. The test statistic F is calculated by dividing one variance by another. In other words, the square of one standard...
3.8K