Eco-Friendly Highly Sensitive Transducers Based on a New KNN-NTK-FM Lead-Free Piezoelectric Ceramic for
Abstract:
High-frequency ultrasonic imaging with improved spatial resolution has gained increasing attention in the field of biomedical imaging. Sensitivity of transducers plays a pivotal role in determining ultrasonic image quality. Conventional ultrasonic transducers are mostly made from lead-based piezoelectric materials that may be harmful to the human body and the environment. In this study, a new (K,Na)NbO3-KTiNbO5-BaZrO3-Fe2O3-MgO (KNN-NTK-FM) lead-free piezoelectric ceramic was utilized in developing eco-friendly transducers for high-frequency biomedical ultrasonic imaging applications. A needle transducer with a small active aperture size of 0.45 × 0.55 mm2 was designed and evaluated. The fabricated transducer exhibits great performance with a high center frequency (52.6 MHz), a good electromechanical coupling (keff ∼ 0.45), a large bandwidth (64.4% at -6 dB), and a very low two-way insertion loss (10.1 dB). Such high sensitivity is superior to those transducers based on other lead-free piezoelectric materials and can even be comparable to the lead-based ones. Imaging performance of the KNN-NTK-FM needle transducer was analyzed by imaging a wire phantom and an agar tissue-mimicking phantom. Imaging capabilities of the transducer were further demonstrated by ex vivo imaging studies on a porcine eyeball and a rabbit aorta. The results suggest that the KNN-NTK-FM piezoceramic has many attractive properties over other lead-free piezoelectric materials in developing eco-friendly highly sensitive transducers for high-frequency biomedical ultrasonic imaging applications.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
09:21Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer
Published on: September 28, 2015
Related Concept Videos
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Frequency-dependent Selection
Phase-lead and Phase-lag Controllers
Transducer Mechanism: Nuclear Receptors
About 48 different soluble family members of nuclear receptors are identified that can be divided into two main classes:
What is a Frequency Distribution
Mean From a Frequency Distribution
When such a data set is encountered,...