Related Experiment Video
Updated: Feb 2, 2026

The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
Comparison between single photon emission computed tomography with computed tomography and planar scintigraphy in
Mitsuru Koizumi1, Masamichi Koyama2
1Departments of Nuclear Medicine, Cancer Institute Hospital, 3-8-31 Ariake, Koto-ku, Tokyo, 135-8550, Japan. mitsuru@jfcr.or.jp.
Objective:
Radio-guided sentinel node (SN) biopsy is a standard method used in the treatment of early breast cancer. Single photon emission computed tomography with computed tomography (SPECT/CT) has been commonly used for SN detection. SPECT/CT adds precise anatomical information of SN sites, and it is reported that more SNs may be detectable on SPECT/CT than on planar imaging. We here investigate which breast cancer patients have benefited from SPECT/CT over planar imaging.
Methods:
A total of 273 breast cancer patients including 80 with ipsilateral breast tumor relapse (IBTR) underwent both multiple-view planar imaging and SPECT/CT for SN detection. The number of SNs, the patients who had benefitted from SPECT/CT, and the SN procedure failure rate were compared between SPECT/CT and planar imaging. Factors influencing the visualization of para-sternal and ipsilateral level II, III nodes, and contralateral axillary nodes were also analyzed using logistic regression analysis.
Results:
The number of hot spots did not differ between SPECT/CT and multiple-view planar imaging. Eight contaminated patients and 52 patients with visualized extra-level I axillary nodes benefited from identifying precise anatomical sites. Even though radioactive nodes could be harvested in most (192/193) of the non-IBTR patients (7/8 in non-SN visible patients), no radioactive nodes could be found during surgery in 11 of 80 IBTR patients. Axillary surgery (dissection) increased the visualization of para-sternal and level II, III axillary nodes, and previous irradiation increased the visualization of contralateral axillary nodes.
Conclusion:
Multiple-view planar imaging was equivalent to SPECT/CT for depicting hot nodes for radio-guided SN detection in breast cancer. SPECT/CT was useful when precise anatomical information was necessary, especially regarding sentinel lymph nodes other than ipsilateral axilla. Logistic regression analysis revealed that axillary surgery (dissection) increased the visualization of para-sternal and level II, III axillary nodes, and the only relevant factor influencing visualization of contralateral axillary SNs was previous radiation to the breast.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Design Example: Traverse Angle Computations

