Related Experiment Video
Updated: Feb 2, 2026

Calibration of Vector Network Analyzer for Measurements in Radio Frequency Propagation Channels
Published on: June 2, 2020
Easily implemented approach for the calibration of alignment and retardation errors in a channeled spectropolarimeter
Abstract:
Calibration of the channeled spectropolarimeter is significant for the quantitative application of this instrument. In current calibration methods for a channeled spectropolarimeter, an absolute angle between the coordinate system of an auxiliary polarizer and the global coordinate system of the instrument is usually indispensable. The effectiveness of calibration depends on the precision of the absolute angle, while it is usually difficult to achieve in a practical calibration process. This paper presents an easily implemented method to simultaneously calibrate the alignment and retardation errors of high-order retarders for a channeled spectropolarimeter. In the presented method, the requirement of an absolute angle between the coordinate system of an auxiliary polarizer and the global coordinate system of the instrument is replaced by only rotating a relative angle in the coordinate system of the auxiliary polarizer itself. First, we theoretically derive the modified reconstruction model considering the alignment errors of high-order retarders. By analyzing and summarizing the modified reconstruction model, the calibration and compensation models of the alignment and retardation errors are further proposed. Then, two linearly polarized beams with a relative angle of 45° between them are utilized to determine the alignment and retardation errors. Based on these results, the alignment and retardation errors can be compensated by a software correction algorithm without any precise mechanical adjustments. The effectiveness and feasibility of the presented method are verified by numerical simulations and experiments. The advantage of easy implementation makes this calibration method more suitable to apply in the laboratory and to be on track for correcting the channeled spectropolarimeter.
Related Concept Videos
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Fundamental Attribution Error
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.

