Related Experiment Video
Updated: Feb 2, 2026

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Published on: September 10, 2014
An ultrasensitive electrochemical immunoassay based on a proximity hybridization-triggered three-layer cascade signal
1State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, P. R. China. ljiang630@163.com.
Abstract:
In this paper, an ultrasensitive electrochemical immunoassay was constructed for the determination of carcinoembryonic antigen (CEA) based on a proximity hybridization-triggered three-layer cascade signal amplification strategy. In the presence of CEA and two antibody-labeled DNA strands (Ab-DNA1 and Ab-DNA2), a sandwich proximate complex was formed which could hybridize with the hairpin DNA (HP1) and open it, initiating the degradation process of exonuclease III (Exo III) accompanied by the release of a sandwich proximate complex used for Cycle I and autogenous yield of a DNA fragment. The fragment was then employed as a ST-DNA (secondary target DNA fragment) for the subsequent binding to the other hairpin DNA (HP2) on the gold (Au) electrode surface to trigger the catalytic hairpin assembly (CHA, Cycle II) and rolling circle amplification (RCA). After the immersion of the above final electrode into methylene blue (MB) solution, an amplified signal was obtained. The proposed electrochemical immunoassay had a good linear relationship in the CEA concentration from 10 fg mL-1 to 100 ng mL-1, and the limit of detection (LOD) was found to be 4.2 fg mL-1. Moreover, with the excellent sensitivity and selectivity based on a three-layer cascade signal amplification strategy, the developed electrochemical immunoassay can pave the way for analysis of other biomarkers.
More Related Videos
14:21High Resolution Fluorescent In Situ Hybridization in Drosophila Embryos and Tissues Using Tyramide Signal Amplification
Published on: October 19, 2017
09:32Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
Published on: September 10, 2017
Related Concept Videos
Intracellular Signaling Cascades
MAPK Signaling Cascades
Amplifying Signals via Enzymatic Cascade
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Rab Cascades
Yeast Signaling