Automated optimization of XCMS parameters for improved peak picking of liquid chromatography-mass spectrometry data
Sascha K Manier1, Andreas Keller2, Markus R Meyer1
1Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Saarland University, Center for Molecular Signaling (PZMS), 66421, Homburg, Germany.
Abstract:
Accurate peak picking and further processing is a current challenge in the analysis of untargeted metabolomics using liquid chromatography-mass spectrometry (LC-MS) data. The optimization of these processes is crucial to obtain proper results. This study investigated and optimized the detection of peaks by XCMS, a widely used R package for peak picking and processing of high-resolution LC-MS metabolomics data by their coefficient of variation using neat standard solutions of drug like compounds. The obtained results were additionally verified by using fortified pooled plasma samples. Settings of the mass spectrometer were optimized by recommendations in literature to enable a reliable detection of the investigated analytes. XCMS parameters were evaluated using a comprehensive parameter sweeping approach. The optimization steps were statistically evaluated and further visualized after principal component analysis (PCA). Concerning the lower concentrated solution in methanol samples, the optimization of both mass spectrometer and XCMS parameters improved the median coefficient of variation from 24% to 7%, retention time fluctuation from 9.3 seconds to 0.54 seconds, and fluctuation of the mass to charge ratio (m/z) from m/z 0.00095 to m/z 0.00028. The number of parent compounds and their related species annotated by CAMERA increased from 88 to 113 while the total amount of features decreased from 3282 to 428. Optimized MS settings such as increased resolution led to a higher specificity of peak picking. PCA supported these findings by showing the best clustering of samples after optimization of both mass spectrometer and XCMS parameters. The results implied that peak picking needs to be individually adapted for the experimental set up. Reducing unwanted variation in the data set was most successful after combining high resolving power with strict peak picking settings.
More Related Videos
Related Concept Videos
Coefficient of Variation
The coefficient of variation is a practical statistical tool in finance. It allows investors to assess the volatility or...
Wave Parameters
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Distributions to Estimate Population Parameter
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...