Frequency and Duration of Infusion Pump Alarms: Establishing National Benchmarks
Abstract:
Reduction of clinical alarms is a priority due to alarm fatigue and the high incidence of nonactionable alarms, especially those generated from physiological monitors. However, research on infusion pump alarm types and frequencies is limited. The purpose of this study was to establish a baseline for infusion pump alarm frequencies and duration in the hospital setting. Frequency and duration of alarms across 29 hospitals using 11,410 infusion pumps revealed 987,240 alarms associated with 568,164 infusions during a consecutive 60-day period. Pump alarms accounted for only 0.8% of infusion time, with an average of 1.74 alarms per delivery and 0.18 alarms per hour. Average alarm duration was 0:02:38 (h:min:s), with 60% of alarms being addressed within 0:01:08. The most frequent alarms were keep vein open (33.77%), hold expired (27.18%), and downstream occlusion (22.94%). The medical/surgical and intensive care unit (ICU) care areas had the highest number of alarms (41.66% and 39.70% of total alarms, respectively), but pediatrics/neonatal ICU had the highest frequency of alarms per delivery (4.91). Intravenous fluids accounted for 47.16% of total alarms, with an average of 3.03 alarms per delivery, whereas parenteral nutrition and propofol had 6.77 and 6.74 average alarms per delivery, respectively. A higher average number of alarms per delivery occurred on Saturdays (1.74) and Sundays (1.73) compared with weekdays. Infusion pump alarm data collected and analyzed were sufficient to establish a reasonable baseline of infusion pump alarm types and relative frequencies for the device.
More Related Videos
10:19Neurodegeneration in an Animal Model of Chronic Amyloid-beta Oligomer Infusion Is Counteracted by Antibody Treatment Infused with Osmotic Pumps
Published on: August 14, 2016
10:41Implantation of Osmotic Pumps and Induction of Stress to Establish a Symptomatic, Pharmacological Mouse Model for DYT/PARK-ATP1A3 Dystonia
Published on: September 12, 2020
Related Concept Videos
National Nursing Organizations I
National Nursing Organizations II
The AACN emphasizes a healthy work environment through six standards to achieve an optimal patient outcome. The standards are appropriate staffing, meaningful recognition, collaboration, authentic leadership, effective communication, and decision-making. In addition, AACN provides certification programs, webinars, journals, and...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Frequency-dependent Selection