Quantitative Determination of Protein-Ligand Affinity by Size Exclusion Chromatography Directly Coupled to

Chengfeng Ren, Aaron O Bailey1, Erica VanderPorten

  • 1Thermo Fisher Scientific , 355 River Oaks Parkway , San Jose , California 95134 , United States.

Analytical Chemistry
|November 28, 2018
PubMed

Related Concept Videos

Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
2.0K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.5K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.7K
Affinity Chromatography01:03

Affinity Chromatography

Affinity chromatography is a powerful technique extensively utilized for separating and purifying specific biomolecules from complex mixtures. It capitalizes on the highly selective binding between an analyte and its counterpart, such as antibody-antigen interactions. The counterpart is immobilized on the stationary phase, forming an affinity column. The stationary phase typically consists of solid support, such as agarose or porous glass beads, immobilizing the affinity ligand. The mobile...
3.0K
G-protein Coupled Receptors01:21

G-protein Coupled Receptors

G-protein coupled receptors are ligand binding receptors that indirectly affect changes in the cell. The actual receptor is a single polypeptide that transverses the cell membrane seven times creating intracellular and extracellular loops. The extracellular loops create a ligand specific pocket which binds to neurotransmitters or hormones. The intracellular loops holds onto the G-protein.
132.0K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.4K