Related Experiment Video
Updated: Feb 2, 2026

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Root and canal morphology of mandibular premolars using cone-beam computed tomography in a Chilean and Belgian
Eugenia Pedemonte1, Carolina Cabrera1, Andrés Torres2
1Department of Endodontics, Universidad de los Andes, Facultad de Odontología. Mons, Álvaro del Portillo 12.455, 7620001, Las Condes, Santiago, Chile.
Objective:
To describe mandibular premolar root and canal morphology and its variability in Chilean and Belgian samples using cone-beam computed tomography.
Methods:
A cross-sectional and descriptive study was conducted. A total of 402 mandibular premolars were examined using cone-beam computed tomography images of Chilean and Belgian patients. Premolars that met the inclusion criteria were studied in relation to the number of roots, number of canals, root canal configuration, presence of C-shaped configuration, tooth length, and root length.
Results:
The mandibular first premolar frequently presented with one root (94% Chilean; 100% Belgian), as did the mandibular second premolar (99% Chilean; 98% Belgian). One canal was present in 69% of Chilean, and 83% of Belgian mandibular first premolars, and in 95% of Chilean and 91% of Belgian second premolars. A type I root canal configuration was found in 69% of Chilean and 83% of Belgian first premolars and in 95% of Chilean and 92% of Belgian second premolars.
Conclusions:
The anatomical parameters analyzed in the Chilean and Belgian samples are similar. However, it should be noted that there are anatomical variations in mandibular premolars.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Cross-Sectional Research
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Finding Volume Using Cross-Sectional Area
Profile Leveling and Cross Sections
Spinal Cord: Cross-sectional Anatomy
Gray Matter and its Components
Central to the gray matter is...