Use of an Additional Nonlocking Screw in Olecranon Fracture Osteosynthesis Changes Failure Mechanism
Abstract:
Hardware-related complications can occur when plate fixation is used to stabilize osteoporotic fractures involving the olecranon. The use of an additional nonlocking screw, placed retrograde into the proximal fracture segment, may improve stability under load. The purpose of this study was to conduct a biomechanical comparison of olecranon repair constructs with and without this additional retrograde screw. Nine matched pairs of elderly fresh-frozen cadaveric upper extremities were used. Two-part olecranon fractures were modeled, and fracture stabilization was performed. Olecranon plates were implanted either with the standard surgical technique (CTRL) or with an additional retrograde screw (EXPT). Dynamic extensions of increasingly loaded forearms were performed, and comparisons of sustained cycles, maximum load, and total work were made. Relative motion of bone segments was tracked, and modes of failure were assessed. Seventy-eight percent of specimens from the CTRL group failed due to relative fragment displacement exceeding 3 mm, while 78% of EXPT specimens failed due to instantaneous catastrophic failure. There were no significant differences in terms of number of survived cycles, maximum load, or work performed between the groups. The addition of a retrograde screw in this plating technique changes the failure mode from fracture displacement to catastrophic failure. The use of a 3.5-mm retrograde screw in the relatively small proximal ulnar fragment should be avoided, but screws with a smaller diameter may still have potential to improve fixation. Further biomechanical and clinical research is necessary to improve strategies for plate fixation of olecranon fractures in the elderly population. [Orthopedics. 2019; 42(1):e74-e80.].
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Related Concept Videos
Nucleophilic Addition to the Carbonyl Group: General Mechanism
A stronger nucleophile can directly attack the electrophilic center, the carbonyl carbon. The HOMO orbital of the nucleophile interacts with the LUMO (π* antibonding) orbital present on the carbonyl carbon. This interaction breaks the π bond and shifts the π...
Radical Anti-Markovnikov Addition to Alkenes: Mechanism
The mechanism starts with chain initiation, which involves two steps. In the first chain initiation step, a weak peroxide bond is homolytically cleaved upon mild heating to form two alkoxy radicals. In the second initiation step, a hydrogen atom is abstracted by the alkoxy...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...