Combined use of Kirschner wires and hinged external fixator for capitellar and trochlear fractures: a minimum
Shu-Kun He1,2, Si-Chun Zhao3, Jin-Hai Guo4
1Department of Orthopedics, West China Hospital, Sichuan University, Chengdu, China.
Background:
Open reduction and internal fixation is the adequate treatment for capitellar and trochlear fractures. Given the low incidence of this type of fractures, it is difficult to constitute a universally accepted method for fixation. Thus, we hypothesised that combined use of Kirschner wires (K-wires), absorbable rods and sutures for fixation and post-operative hinged external fixator for early rehabilitation exercise can restore elbow joint function well.
Methods:
This retrospective study included 20 patients with a mean age of 48.3 (range 16-76) years. According to the Dubberley classification, fractures were classified on plain radiographs, computed tomography images and intra-operative findings. All patients were evaluated by the range of motion of the elbow and the Broberg-Morrey score.
Results:
All fractures had healed without non-union, and the average time was 13.6 (range 8-17) weeks. The mean follow-up was 42.5 (range 24-80) months. The mean flexion was 117.1° (range 90°-135°), and the mean extension was 17.5° (range 0°-45°). The mean pronation was 74.4° (range 45°-85°), and the mean supination was 84.3° (range 60°-90°). The average Broberg-Morrey score was 86.2 (range 68-98) points with 10 excellent, 7 good and 3 fair results.
Conclusion:
K-wires, absorbable rods and sutures combined with hinged external fixator are feasible for fixation of capitellar and trochlear fractures. However, due to the absence of a control group (such as Herbert screw fixation), comparative studies are still needed to demonstrate the safety and reliability of K-wires for fixation.
Related Concept Videos
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Holter Monitor: 24-Hour Monitoring
Internal and External Forces
External and Internal Respiration
External Anatomy of the Kidney
The kidneys are located in the retroperitoneal space on either side of the vertebral column, protected posteriorly by the 11th and 12th ribs. The right kidney sits slightly lower than the left owing to the presence of the liver...