A comprehensive dosimetric study of Monte Carlo and pencil-beam algorithms on intensity-modulated proton therapy for
Xiaoying Liang1, Zuofeng Li1, Dandan Zheng2
1Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA.
Abstract:
PB algorithms are commonly used for proton therapy. Previously reported limitations of the PB algorithm for proton therapy are mainly focused on high-density gradients and small-field dosimetry, the effect of PB algorithms on intensity-modulated proton therapy (IMPT) for breast cancer has yet to be illuminated. In this study, we examined 20 patients with breast cancer and systematically investigated the dosimetric impact of MC and PB algorithms on IMPT. Four plans were generated for each patient: (a) a PB plan that optimized and computed the final dose using a PB algorithm; (b) a MC-recomputed plan that recomputed the final dose of the PB plan using a MC algorithm; (c) a MC-renormalized plan that renormalized the MC-recomputed plan to restore the target coverage; and (d) a MC-optimized plan that optimized and computed the final dose using a MC algorithm. The DVH on CTVs and on organ-at-risks (OARs) from each plan were studied. The Mann-Whitney U-test was used for testing the differences between any two types of plans. We found that PB algorithms significantly overestimated the target dose in breast IMPT plans. The median value of the CTV D99% , D95% , and Dmean dropped by 3.7%, 3.4%, and 2.1%, respectively, of the prescription dose in the MC-recomputed plans compared with the PB plans. The magnitude of the target dose overestimation by the PB algorithm was higher for the breast CTV than for the chest wall CTV. In the MC-renormalized plans, the target dose coverage was comparable with the original PB plans, but renormalization led to a significant increase in target hot spots as well as skin dose. The MC-optimized plans led to sufficient target dose coverage, acceptable target hot spots, and good sparing of skin and other OARs. Utilizing the MC algorithm for both plan optimization and final dose computation in breast IMPT treatment planning is therefore desirable.
Related Concept Videos
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...
Targeted Cancer Therapies
There are several types of targeted therapies against...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Trial and Error and Algorithm
Sound Intensity
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...