Related Experiment Video
Updated: Feb 1, 2026

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy
Published on: August 22, 2018
Assessment of S values for I131 and Y90 based on the Digimouse voxel phantom
Ashutosh Sinha1, Navin Singh2, Bhanu Mani Dixit1
1Department of Physics, Faculty of Physical Sciences, Shri Ramswaroop Memorial University, Lucknow, Uttar Pradesh, India.
Introduction:
Most preclinical studies using radiopharmaceuticals have been carried out on mice. In nuclear medicine and radioimmunotherapy procedures, I131 and Y90 have been widely used. For better estimation of doses from these procedures, S value plays a vital role. In this study, we have evaluated S values for major source and target combinations of Digimouse voxel phantom.
Materials And Methods:
We have used the Digimouse voxel phantom which was incorporated in Monte Carlo code FLUKA. Simulation studies were performed using Monte Carlo simulation code FLUKA. Latest publication of International Commission on Radiological Protection (ICRP) report 110 was used for assigning the values of organ compositions and densities. Photon and electron spectra for I131 and Y90 have been taken from the ICRP publication 107. For Digimouse voxel phantom, we have simulated 9 source regions with an assumed uniform distribution of I131 and Y90.
Results And Discussion:
S values have been evaluated for I131 and Y90 for different source and target combinations of Digimouse voxel phantom and presented in tabular form. The S values can be applied prospectively or retrospectively to the calculation of radiation doses internally exposed to I131 and Y90, including nuclear medicine and radioimmunotherapy procedures. These S values have been very important for the calculation of absorbed doses for various organs similar in size to present study for mice.
Conclusion:
In this study S value for I131 and Y90 were evaluated for major organs of digimouse voxel phantom. These S values are very important for absorbed dose calculation for various organs of a mouse.
Related Concept Videos
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Absolute and Local Extreme Values
Finding Critical Values for Chi-Square