Related Experiment Video
Updated: Feb 1, 2026

Drug Repurposing Hypothesis Generation Using the "RE:fine Drugs" System
Published on: December 11, 2016
Evaluation of Repurposing Archetypal Preventive Radiological/Nuclear Detectors for the Consequence Management Mission
Stephen V Musolino1, Brooke Buddemeier2, Charles Finfrock1
1Brookhaven National Laboratory, P.O. Box 5000, Upton, NY 11973.
Abstract:
In the first hours or days after an unplanned release of radioactive material to the environment, the radiation detection instruments most widely available to local first responders may be those currently fielded for interdiction missions. This study investigated how such preventative radiological/nuclear detection instruments could perform if repurposed for consequence management missions. A representative sample of three archetypes (body-worn, human-carried, and other/large-detection-volume equipment) encompassed six categories: personal radiation detector, extended-range personal radiation detector, personal emergency radiation detector, radioisotope identification device, human-portable detector/backpack, and vehicle-mounted large-detection-volume detector. Overall 19 models of equipment were included in the study. Laboratory evaluations were designed to assess the capabilities of the instruments in four consequence management missions: exposure rate, integrated exposure, radiation survey, and contamination screening. As applicable, the evaluations included measurement of exposure rate, integrated exposure, overrange response, and angular response. The results were compared to benchmarks from the American National Standards Institute N42.49A. The performance of the instruments for initial screening for contamination was assessed by an automated radioactive source moving past the detectors at various speeds and distances. The results demonstrate that if the equipment is used in accordance with the mission analysis and categories and within the original equipment manufacturer specifications, it is possible to achieve sufficient accuracy to estimate and document doses to responders, plan entries into contaminated areas, detect contamination, and protect the public until such time as outside resources arrive with sufficient numbers of standard health physics instruments and personnel dosimetry to replace the preventative radiological/nuclear detection instruments. This evaluation campaign was conducted to complement the National Council on Radiation Protection and Measurements Report 179, Guidance for Emergency Response Dosimetry.
Related Concept Videos
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Stress Prevention and Stress Management Techniques II
Type A Personality: Driven and Easily Stressed
Individuals with Type A personalities are often highly competitive and ambitious and operate with a strong sense of urgency. Commonly labeled as...
Stress Prevention and Stress Management Techniques I
Conscientiousness
Conscientious individuals tend to be organized, responsible, and disciplined. They prioritize completing tasks and following structured routines,...
Stress Prevention and Stress Management Techniques V
Stress Prevention and Stress Management Techniques VI
Motivation and Self-Determination
Motivation, the driving force behind behavior, plays a pivotal role at every stage of the change process. The research...
Stress Prevention and Stress Management Techniques IV

