Electrical Stun Gun and Modern Implantable Cardiac Stimulators
Eugenio Mattei1, Federica Censi, Giovanni Calcagnini2
11Italian National Institute of Health, Rome, Italy.
Abstract:
The aim of the study is to investigate systematically the possible interactions between two types of stun guns and last-generation pacemakers and implantable defibrillators. Experimental measurements were performed on pacemakers and implantable defibrillators from five leading manufacturers, considering the effect of stun gun dart positioning, sensing modality, stun gun shock duration, and defibrillation energy level. More than 300 measurements were collected. No damage or permanent malfunction was observed in either pacemakers or implantable defibrillators. During the stun gun shock, most of the pacemakers entered into the noise reversion mode. However, complete inhibition of the pacing activity was also observed in some of the pacemakers and in all the implantable defibrillators. In implantable defibrillators, standard stun gun shock (duration 5 s) caused the detection of a shockable rhythm and the start of a charging cycle. Prolonged stun gun shocks (10-15 s) triggered the inappropriate delivery of defibrillation therapy in all the implantable defibrillators tested. Also in this case, no damage or permanent malfunction was observed. For pacemakers, in most cases, the stun guns caused them either to switch to the noise reversion mode or to exhibit partial or total pacing inhibition. For implantable defibrillators, in all cases, the stun guns triggered a ventricular fibrillation event detection. No risks resulted when the stun gun was used by a person wearing a pacemaker or an implantable defibrillator. This work provides novel and up-to-date evidence useful for the evaluation of risks to pacemaker/implantable defibrillator wearers due to stun guns.
More Related Videos
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
10:11Updated Technique for Reliable, Easy, and Tolerated Transcranial Electrical Stimulation Including Transcranial Direct Current Stimulation
Published on: January 3, 2020
Related Concept Videos
Modern Molecular Taxonomy
Finding Electric Potential From Electric Field
Determining Electric Field From Electric Potential
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
Electric Potential Energy in a Uniform Electric Field
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Electrical Systems
To derive the transfer function, consider an RLC...