3-Dimensional Quantification of Composite Pleural Plaque Volume in Patients Exposed to Asbestos Using High-resolution
Gael Dournes1,2,3, Adrian Dubois3, Ilyes Benlala1,2,3
1Cardio-thoracic Research Center of Bordeaux, U1045, CIC 1401.
Rationale:
As pleural plaque has been reported as a risk factor in the occurrence of lung cancer and mesothelioma, a reproducible and precise method of measurement of pleural plaque volume (PPV) is needed to further describe these relationships. The aim of the study was to assess the reproducibility of a 3-dimensional computed tomography (3D-CT) volumetric analysis of PPV in patients with occupational exposure to asbestos.
Material And Methods:
A total of 28 patients were retrospectively randomly selected from the multicenter APEXS (Asbestos Post Exposure Survey) study, which was held between 2003 and 2005. All patients underwent a 3D-CT scan. Two readers specialized in chest radiology completed the 3D semiautomated quantification of lung volume using dedicated software. They also had to categorize the visual extent of pleural plaque in terms of thickness and circumference. Reproducibility of the continuous PPV variable was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Reproducibility of categorical variables was assessed using the κ test.
Results:
Intraobserver reproducibility of PPV was almost perfect (ICC=0.98 [95% interval: 0.97-0.99]), and interobserver reproducibility was very good (ICC=0.93 [0.88-0.97]). At Bland-Altman analysis, the mean differences were 0.1 (limit of agreement: -11.0 to 11.2) and 3.7 cc (-17.8 to 25.2), respectively. Visual analysis of both plaque in terms of thickness and circumference were fair to moderate, with κ values ranging from 0.30 to 0.60.
Conclusions:
3D semiautomatic quantification of PPV is feasible and reproducible using CT in patients with occupational exposure to asbestos. PPV measurement may be useful to correlate with other asbestos-related disease outcomes and prognosis.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's...
Reliability and Validity
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)