Ratiometric Electrogenerated Chemiluminescence Cytosensor Based on Conducting Polymer Hydrogel Loaded with Internal
Caifeng Ding1, Yunxia Li1, Lei Wang1
1Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering , Qingdao University of Science and Technology , Qingdao 266042 , People's Republic of China.
Abstract:
A sensitive and reliable bimodal electrochemiluminescent (ECL) system based on CdTe quantum dots (QDs) and luminol as double luminophores is constructed. CdTe QDs tagged with the aptamer (CdTe-Apt 2) of cancer cells are used as the detection signals, while luminol molecules are used as internal standards. The electrodeposited polyaniline-based conducting polymer hydrogel (CPH) on the electrode surfaces improves the biocompatibility and conductivity of the sensing interfaces effectively. Furthermore, electron transfer is probably much easier when luminol and coreactant potassium persulfate (K2S2O8) are immobilized in the CPH in comparison to that in solution. Cancer cells are captured to the electrode surface by another aptamer linked to the Au nanoparticles immobilized in the CPH through Au-S bonds. In the developed bimodal ECL system, an internal standard method is used to quantify cancer cells by comparing the differences in sensitivity of the double-peak ECL signals with that of target analytes. The internal standard method of ECL strategy can provide very accurate detection results in a complex environment because interferences in the system can be eliminated through the self-calibration of two emission spectra. A linear relation is found on the basis of a plot of the ΔECLCdTe/ΔECLluminol against the concentration of cancer cells within 100-6500 cells mL-1 under optimized conditions. The developed ratiometric ECL cytosensor with internal standard can significantly improve the accuracy and reliability of cell assays in complex biological media, demonstrating promising applications in healthcare monitoring and clinical diagnostics.
Related Concept Videos
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Polymers
Polymers
Internal Receptors
Internal Energy
Measurement: Standard Units