Frequency response of the leap motion controller and its suitability for measuring tremor
Clay J Kincaid1, Austin C Vaterlaus1, Nathan R Stanford2
1Mechanical Engineering, Brigham Young University, Provo, UT 84602, United States.
Abstract:
Although tremor is one of the most common movement disorders, it is evaluated using relatively coarse clinical scales. We propose to measure tremor in clinical settings using the Leap Motion Controller (LMC), which is a markerless motion capture sensor that has a low cost, zero set-up time, and dynamic accuracy of 1.2 mm. However, the frequency response of the LMC has not been characterized, so its ability to track oscillations such as tremor is unknown. To characterize the frequency response of the LMC, we measured the position of a mannequin hand simultaneously with the LMC and a high-resolution encoder while the mannequin hand oscillated at various combinations of frequency (1-15 Hz) and amplitudes (0.01-30 mm). We calculated the magnitude ratio and phase shift of the LMC and found the bandwidth of the LMC to range from 0-3 Hz to 0-5 Hz for tremor amplitudes greater than the dynamic accuracy. This bandwidth is too small to accurately measure most tremors. However, we developed an inverse filter to estimate the actual tremor amplitude and phase despite the limited bandwidth. Over the combinations of frequency and amplitude mentioned above, the inverse filter estimated the actual tremor amplitude and phase with errors of 3% and 2%, respectively.
Related Concept Videos
Load-frequency control
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...
Frequency Response of a Circuit
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Frequency Response of Op Amp Circuits
Frequency Response and Gain:
The gain of the op-amp, A(ω), is not a constant but a function of the input signal frequency. An op-amp can maintain a constant gain at low frequencies, known...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...