Related Experiment Video
Updated: Feb 1, 2026

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds
Karen D Oliver1, Tamira A Cousett2, Donald A Whitaker1
1U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, Research Triangle Park, NC, USA.
Refrigerated volatile organic compound (VOC) samples collected on Carbopack X tubes remained stable for over 6 months, suggesting current storage limits may be relaxed. Interlaboratory comparisons showed good agreement for benzene and VOC monitoring using EPA Methods 325A/325B.
Area of Science:
- Environmental Science
- Analytical Chemistry
- Occupational Health
Background:
- U.S. Environmental Protection Agency (EPA) Methods 325A and 325B are used for diffusive monitoring of benzene and volatile organic compounds (VOCs).
- Carbopack X sorbent tubes are employed for collecting these VOCs.
- Standard operating procedures specify a maximum 30-day storage for collected samples.
Purpose of the Study:
- To evaluate the sample integrity of VOCs collected on Carbopack X sorbent tubes.
- To conduct an interlaboratory comparison of VOC analysis using EPA Methods 325A and 325B.
- To assess the feasibility of extending the recommended sample storage duration.
Main Methods:
- VOC samples were stored under refrigeration for up to 240 days.
- Sample analysis was performed using thermal desorption/gas chromatography-mass spectrometry (TD/GC-MS).
- Three commercial laboratories participated in an interlaboratory comparison, analyzing field and laboratory-collected VOC samples according to Method 325B.
Main Results:
- Refrigerated VOC samples on Carbopack X tubes demonstrated stability for 6 months or longer.
- Interlaboratory comparison results for laboratory-collected samples were within ±25% of theoretical concentrations.
- Differences among laboratories for ambient samples were minimal (<1 ppbv), indicating good precision and agreement.
Conclusions:
- The 30-day storage limitation for VOCs collected on Carbopack X tubes may be extended, reducing logistical constraints.
- EPA Methods 325A and 325B are reliable for diffusive VOC monitoring, with consistent results across multiple laboratories.
- The study supports the extended use of refrigerated Carbopack X passive samplers for environmental monitoring.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
10:48EPA Method 1615. Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. I. Collection of Virus Samples
Published on: March 28, 2015
Related Concept Videos
Organic Compounds
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Volatilization
Diffusion
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...