Evaluation of the physical and biological dosimetry methods in iodine-131-treated patients
Ayşegül Ozdal1, Taner Erselcan2, Öztürk Özdemir3
1Department of Nuclear Medicine, Kayseri Training and Research Hospital, 38010 Kayseri, Turkey.
Abstract:
The aim of the study was to compare physical and biological dosimetry methods in iodine-131 (I-131)-receiving patients. The present study comprised of 47 patients (mean age: 47.9 ± 15.8 years), treated with I-131. Group I consisted of 17 patients with hyperthyroidism and mean administered activity of this group was 432.9 ± 111 MBq. There were 15 follow-up patients of differentiated thyroid cancer (DTC) in Group II with mean administered activity of 185 ± 22.2 MBq, who were administered scanning dose of I-131. Group III comprised of 15 patients with DTC, ablated with high-dose of I-131, and this group's mean administered activity was 4347.5 ± 695.6 MBq. The whole-body absorbed doses were calculated in all patients both with the Medical Internal Radiation Dosimetry (MIRD) method using MIRDOSE3 software and cytokinesis-block micronucleus (MN) assay-based MN analysis and were compared. The whole-body absorbed dose, calculated by MIRD method, showed very good correlation with the administered I-131 activity (r = 0.89, P < 0.001), but it was moderate in the MN method (r = 0.52, P < 0.01). Absorbed dose estimations with MIRD method were 49.2 ± 20.8 mGy in Group I, 6.5 ± 1.6 mGy in Group II, and 154.3 ± 47.8 mGy in Group III; the differences were statistically significant (P < 0.001), as expected. Pre- and posttreatment MN frequencies differed significantly in all groups (P < 0.05). The whole-body absorbed doses, based on MN method, were 68.2 ± 17.5, 46.0 ± 11.4, and 90.5 ± 26.9 mGy in Groups I-III, respectively. The difference was significant between Group II and Group III (P < 0.01). The mean absorbed dose was 74.6 ± 27.9 mGy with MN versus 68.0 ± 67.1 mGy in MIRD method (P = 0.087) in the entire study population and the correlation was moderate (r = 0.73, P < 0.001). The whole-body absorbed doses, estimated by MN method, showed moderate correlation with administered radioiodine activities in low radioiodine doses and had significantly different and fluctuating values as compared to MIRD method in patients treated with I-131.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:39Physical, Chemical and Biological Characterization of Six Biochars Produced for the Remediation of Contaminated Sites
Published on: November 28, 2014
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Biological Methods for Microbial Control
Physical Methods for Controlling Microbial Growth: Temperature
Physical and Chemical Properties of Matter
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
What is Conservation Biology?