Related Experiment Video
Updated: Feb 1, 2026

Multifractal Spectrum Analysis for Assessing Pulmonary Nodule Malignancy
Published on: January 10, 2025
Biopsy of peripheral lung nodules utilizing cone beam computer tomography with and without trans bronchial access
Michal Jan Sobieszczyk1, Zhuhui Yuan2, Wei Li2
1Department of Pulmonary and Critical Care Medicine, San Antonio Military Medical Center, San Antonio, Texas, USA.
Background:
Currently there are several techniques for endoscopic diagnosis of parenchymal lung abnormalities. Electromagnetic navigation with or without endobronchial ultrasound for diagnosis of the above has been well described. Bronchoscopic Trans Bronchial Access Tool is a novel endoscopic technique that creates a virtual pathway to the lesion and is less limited by location of the airway. The CrossCountryTM Transbronchial Access Tool (CovidienTM, Plymouth, MN, USA) is a Food and Drug Administration (FDA) approved off airway device that utilizes a catheter equipped guide sheath for a trans-parenchymal approach to a distal lesion. Cone beam computer tomography (CBCT) is a real-time onsite extrathoracic navigational modality used in the bronchoscopy suite that allows for an open working channel. All three of the above modalities can have reasonable diagnostic yields when used independently. While utilizing the above tools we frequently found ourselves in situations where one technique was not enough, prompting the use of a combination of modalities to obtain the most efficient and accurate diagnosis. We are reporting the feasibility and safety of utilizing these three modalities in conjunction with one another.
Methods:
Patients with peripheral pulmonary nodules on chest computed tomography underwent a navigation bronchoscopy under general anesthesia. CBCT and radial ultrasound was used in every case to confirm navigation to the target lesion. Lesions without definitive airways leading to them were accessed with the transbronchial access tool (TBAT).
Results:
Electromagnetic bronchoscopy using CBCT and radial US was performed on 22 patients from April 2016 to September 2016. The TBAT tool was used in 7 patients. The overall diagnostic yield was 77.2% (17 of 22). Diagnostic yield of with use TBAT was 100% (7 of 7). There were no complications. Average case length was 79.95 (range, 50-124) minutes and average fluoroscopy time was 10.39 (1-21.7) minutes.
Conclusions:
TBAT is a useful and safe tool when accessing peripheral pulmonary nodules and is used in conjunctions with electromagnetic navigation and CBCT.
More Related Videos
07:53Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
06:03Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015
Related Concept Videos
The Bronchial Tree
The trachea, commonly known as the windpipe, is a tube that connects the larynx (voice box) to the bronchi. At a point called the carina, it bifurcates into two primary bronchi. The right primary bronchus is wider, shorter, and more vertical than the left primary...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Overview of Microsoft Excel as a Data Analysis Tool
Lung Capacity
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...