The choice of embedding media affects image quality, tissue R2* , and susceptibility behaviors in post-mortem brain
Petr Dusek1,2, Vince Istvan Madai3, Till Huelnhagen4
1Department of Neurology, Charles University, 1st Faculty of Medicine and General University Hospital in Prague, Praha, Czech Republic.
Purpose:
The quality and precision of post-mortem MRI microscopy may vary depending on the embedding medium used. To investigate this, our study evaluated the impact of 5 widely used media on: (1) image quality, (2) contrast of high spatial resolution gradient-echo (T1 and T2* -weighted) MR images, (3) effective transverse relaxation rate (R2* ), and (4) quantitative susceptibility measurements (QSM) of post-mortem brain specimens.
Methods:
Five formaldehyde-fixed brain slices were scanned using 7.0T MRI in: (1) formaldehyde solution (formalin), (2) phosphate-buffered saline (PBS), (3) deuterium oxide (D2 O), (4) perfluoropolyether (Galden), and (5) agarose gel. SNR and contrast-to-noise ratii (SNR/CNR) were calculated for cortex/white matter (WM) and basal ganglia/WM regions. In addition, median R2* and QSM values were extracted from caudate nucleus, putamen, globus pallidus, WM, and cortical regions.
Results:
PBS, Galden, and agarose returned higher SNR/CNR compared to formalin and D2 O. Formalin fixation, and its use as embedding medium for scanning, increased tissue R2* . Imaging with agarose, D2 O, and Galden returned lower R2* values than PBS (and formalin). No major QSM offsets were observed, although spatial variance was increased (with respect to R2* behaviors) for formalin and agarose.
Conclusions:
Embedding media affect gradient-echo image quality, R2* , and QSM in differing ways. In this study, PBS embedding was identified as the most stable experimental setup, although by a small margin. Agarose and Galden were preferred to formalin or D2 O embedding. Formalin significantly increased R2* causing noisier data and increased QSM variance.
Insights
The choice of embedding medium significantly impacts post-mortem MRI microscopy quality. Phosphate-buffered saline (PBS) offered the most stable results for gradient-echo imaging and quantitative susceptibility mapping.
Area of Science:
- Neuroimaging
- Biomedical Engineering
- Materials Science
Background:
- Post-mortem MRI microscopy requires precise sample preparation.
- The embedding medium can influence image quality and quantitative measurements.
Purpose of the Study:
- To evaluate the impact of five embedding media on post-mortem brain MRI microscopy.
- Assessed effects on image quality, contrast, relaxation rates (R2*), and quantitative susceptibility mapping (QSM).
Main Methods:
- Five formaldehyde-fixed brain slices were scanned using 7.0T MRI.
- Tested media included formalin, phosphate-buffered saline (PBS), deuterium oxide (D2O), perfluoropolyether (Galden), and agarose gel.
- Analyzed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), R2*, and QSM.
Main Results:
- PBS, Galden, and agarose yielded higher SNR/CNR than formalin and D2O.
- Formalin increased tissue R2* and QSM variance, leading to noisier data.
- Agarose, D2O, and Galden resulted in lower R2* values compared to PBS and formalin.
Conclusions:
- Embedding media significantly influence gradient-echo image quality, R2*, and QSM.
- PBS provided the most stable experimental setup for post-mortem MRI.
- Agarose and Galden are preferable to formalin or D2O for improved imaging outcomes.
Related Concept Videos
Mate Choice
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
What is Behavior?
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance