Related Experiment Video
Updated: Feb 1, 2026

Comparison of Scale in a Photosynthetic Reactor System for Algal Remediation of Wastewater
Published on: March 6, 2017
Performance and dynamic characteristics of microbial communities in multi-stage anaerobic reactors treating
Erming Ouyang1, Yao Lu1, Jiating Ouyang1
1School of Civil Engineering and Architecture, Nanchang University, Nanchang 330031, China.
Abstract:
To treat gibberellin (GA) wastewater, a full-scale, multi-stage combined contact process was developed. This whole process employs three anaerobic reactors followed by micro-aerobic, anoxic/aeration and biological oxidation treatment. Pollutant removal results showed that the combined process could remove more than 98% of the chemical oxygen demand (COD), NH3N, and SO42- pollutants because of the different microbial communities in each reactor. 16S rRNA gene sequencing was used to examine the microbial communities in the internal circulation (IC) and in the two up flow anaerobic sludge blanket (UASB) reactors, as well as to investigate the effect of sampling elevation on the microbial community. The results showed that Firmicutes and Euryarchaeota were the most dominant phyla at the bacterial and archaeal levels, respectively. High levels of Synergistaceae_uncultured were detected in IC and UASB1. Chloroflexi_uncultured was the dominant genus of bacterial communities within UASB2, and Methanosaeta was the dominant genus of archaeal communities. Principal coordinates analysis (PCoA) revealed variations among the microbial communities in 9 samples, and Venn analysis showed different operational taxonomic units (OTUs) among samples collected at various elevations within the three anaerobic reactors. However, partial Mantel tests indicated no significant correlation between the microbial community structure and elevation in the three anaerobic reactors.
Related Concept Videos
Gene Regulation in Microbial Communities: Quorum Sensing
What are Populations and Communities?
Characteristics of Life
Characteristics of Fluids
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
Characteristics of JFET
The core of a JFET's operation is controlling drain current by modulating the gate-source voltage. When the drain and gate voltage are set to zero, the JFET exhibits no net current flow, representing a state of equilibrium. The drain current increases linearly as the...

