Related Experiment Video
Updated: Feb 1, 2026

Study of Protein Dynamics via Neutron Spin Echo Spectroscopy
Published on: April 13, 2022
A phase-cycled temperature-sensitive fast spin echo sequence with conductivity bias correction for monitoring of mild
Mingming Wu1, Hendrik T Mulder2, Yuval Zur3
1Munich School of Bioengineering, Technical University of Munich, Boltzmannstr. 11, 85748, Garching bei München, Germany. mingming.wu@tum.de.
Objective:
Mild hyperthermia (HT) treatments are generally monitored by phase-referenced proton resonance frequency shift calculations. A novel phase and thus temperature-sensitive fast spin echo (TFSE) sequence is introduced and compared to the double echo gradient echo (DEGRE) sequence.
Theory And Methods:
For a proton resonance frequency shift (PRFS)-sensitive TFSE sequence, a phase cycling method is applied to separate even from odd echoes. This method compensates for conductivity change-induced bias in temperature mapping as does the DEGRE sequence. Both sequences were alternately applied during a phantom heating experiment using the clinical setup for deep radio frequency HT (RF-HT). The B0 drift-corrected temperature values in a region of interest around temperature probes are compared to the temperature probe data and further evaluated in Bland-Altman plots. The stability of both methods was also tested within the thighs of three volunteers at a constant temperature using the subcutaneous fat layer for B0-drift correction.
Results:
During the phantom heating experiment, on average TFSE temperature maps achieved double temperature-to-noise ratio (TNR) efficiency in comparison with DEGRE temperature maps. In-vivo images of the thighs exhibit stable temperature readings of ± 1 °C over 25 min of scanning in three volunteers for both methods. On average, the TNR efficiency improved by around 25% for in vivo data.
Conclusion:
A novel TFSE method has been adapted to monitor temperature during mild HT.
More Related Videos
10:02Neutron Spin Echo Spectroscopy as a Unique Probe for Lipid Membrane Dynamics and Membrane-Protein Interactions
Published on: May 27, 2021
09:23Inducing Targeted Mild Hyperthermia in Murine Tumor Models through Photothermal Conversion of Near-infrared Light by Intratumoral Gold Nanorods
Published on: October 10, 2025
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Confirmation Biases
Hindsight Biases
Bias
In statistics, a sampling bias is created when a sample is collected from a population, and some members of the population are not as likely to be chosen as others (remember, each member...
Distance Corrections
NMR Spectroscopy: Spin–Spin Coupling