Related Experiment Video
Updated: Feb 1, 2026

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
Published on: August 4, 2020
Accelerated imaging of metallic implants using model-based nonlinear reconstruction
Xinwei Shi1,2, Evan Levine1,2, Hans Weber1
1Department of Radiology, Stanford University, Stanford, California.
Purpose:
To accelerate imaging near metallic implants with multi-spectral imaging (MSI) techniques by exploiting a signal model in the spectral dimension.
Methods:
MSI techniques resolve metal-induced field perturbations by acquiring separate 3D spatial encodings at multiple excitation frequencies, which are referred to as spectral bins. The proposed model-based reconstruction exploits the correlation between spectral bins in image reconstruction by enforcing a signal model to describe the signal profile across bins. This work evaluates the accuracy of the MSI signal model in simulations and in vivo experiments. The proposed model-based reconstruction was evaluated in 6 subjects at an overall undersampling factor of 17.4 and compared with model-free parallel imaging and compressed sensing (PI & CS). The quality of reconstructed images was evaluated using normalized RMS error (nRMSE) and structural similarity index (SSIM) comparisons, with paired Wilcoxon tests in 6 subjects used to determine whether there was a significant difference in the metrics.
Results:
Both simulations and in vivo experiments show that the proposed signal model can represent the MSI signal profiles in the spectral dimension compactly and accurately. In the in vivo experiments, the model-based reconstruction significantly improved image quality over model-free PI & CS, with P < 0.05 for both nRMSE and SSIM at 17.4× acceleration.
Conclusion:
This work presents the feasibility of using a model-based reconstruction to accelerate MSI techniques for faster MR imaging near metal.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Bonding in Metals
Alkali Metals
Table 1: Properties of the alkali metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Accelerators
The effectiveness of calcium chloride can...
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...