Related Experiment Video
Updated: Feb 1, 2026

Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
Published on: May 4, 2011
Comparison of tissue oxygenation achieved breathing oxygen from a demand valve with four different mask
Denise F Blake1,2, Melissa Crowe3, Daniel Lindsay4
1Marine Biology and Aquaculture, James Cook University, Townsville.
Introduction:
High concentration normobaric oxygen (O₂) is a priority in treating divers with suspected decompression illness. The effect of different O₂ mask configurations on tissue oxygenation when breathing with a demand valve was evaluated.
Methods:
Sixteen divers had tissue oxygen partial pressure (PtcO₂) measured at six limb sites. Participants breathed O₂ from a demand valve using: an intraoral mask (IOM®) with and without a nose clip (NC), a pocket face mask and an oronasal mask. In-line inspired O₂ (FIO₂) and nasopharyngeal FIO₂ were measured. Participants provided subjective ratings of mask comfort, ease of breathing and holding in position.
Results:
PtcO₂ values and nasopharyngeal FIO₂ (median and range) were greatest using the IOM with NC and similar with the IOM without NC. O₂ measurements were lowest with the oronasal mask which also was rated as the most difficult to breathe from and to hold in position. The pocket face mask was reported as the most comfortable to wear. The NC was widely described as uncomfortable. The IOM and pocket face mask were rated best for ease of breathing. The IOM was rated as the easiest to hold in position.
Conclusion:
Of the commonly available O₂ masks for use with a demand valve, the IOM with NC achieved the highest PtcO₂ values. PtcO₂ and nasopharyngeal FIO₂ values were similar between the IOM with and without NC. Given the reported discomfort of the NC, the IOM without NC may be the best option.
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Transport in the Blood
Oxygenic Photosynthesis
Oxygen Requirements and Growth Patterns