Dosimetry of indigenously developed 177Lu patch source for surface brachytherapy-Experimental and Monte Carlo methods
Sridhar Sahoo1,2, Vandana Shrivastava1, T Palani Selvam1,2
1Radiological Physics & Advisory Division, Bhabha Atomic Research Centre, Mumbai-400 085, India.
None:
This paper describes the evaluation of dosimetry characteristics of an in-house developed 177Lu skin patch source for treatment of non-melanoma skin cancer. A 177Lu skin patch source based on Nafion-115 membrane backbone containing 3.46 ± 0.01 mCi of activity was used. Activity measurement of the patch source was based on gamma ray spectrometry using a HPGe detector. The efficiencies of the HPGe detector were fitted using an orthogonal polynomial function. The absorbed dose rate to water at 5 μm depth in water was determined using an extrapolation chamber, EBT3 Gafchromic film and compared with Monte Carlo methods. The correction factors such as Bragg-Gray stopping power ratio of water-to-air and chamber wall material being different from water, needed to be applied on measurements for establishing the dose rate at 5 μm depth, were calculated using the Monte Carlo method. Absorbed dose rate at 5 μm depth in water (surface dose rate) measured using an extrapolation chamber and EBT3 Gafchromic film were 9.9 ± 0.7 and 8.2 ± 0.1 Gy h-1 mCi-1 respectively for the source activity of 3.46 ± 0.01 mCi. The surface dose rate calculated using the Monte Carlo method was 8.7 ± 0.2 Gy h-1 mCi-1, which agrees reasonably well with measurement. The measured dose rate per mCi offers scope for ascertaining treatment time required to deliver the dose for propitious therapeutic outcome. Additionally, on-axis depth dose and lateral dose profiles at 5 μm and 1 mm depth in water phantom were also calculated using the Monte Carlo method.
Related Concept Videos
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
Development of Analytical Methods
Long-patch Base Excision Repair
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Sustainable Development