Time domain characterization for sleep apnea in oronasal airflow signal: a dynamic threshold classification approach

Jungyoon Kim1,2, Hisham ElMoaqet1,3, Dawn M Tilbury1

  • 1Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48105, United States of America.

Physiological Measurement
|December 8, 2018
PubMed
Abstract

Related Concept Videos

Sleep Apnea01:21

Sleep Apnea

Sleep apnea is a condition where breathing stops intermittently during sleep, often leading to significant health issues. Each episode can last from 10 to 20 seconds or more and is frequently accompanied by a brief arousal from sleep. This disturbance, largely unnoticed by the individual, can lead to severe daytime fatigue. Commonly, individuals seek help after being informed by their partners about loud snoring and noticeable breathing pauses during sleep.
The condition is more prevalent among...
559
Classification of Signals01:30

Classification of Signals

In signal processing, signals are classified based on various characteristics: continuous-time versus discrete-time, periodic versus aperiodic, analog versus digital, and causal versus noncausal. Each category highlights distinct properties crucial for understanding and manipulating signals.
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
1.4K
Linear Approximation in Time Domain01:21

Linear Approximation in Time Domain

Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
373
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
407
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
412
Basic Continuous Time Signals01:22

Basic Continuous Time Signals

Basic continuous-time signals include the unit step function, unit impulse function, and unit ramp function, collectively referred to as singularity functions. Singularity functions are characterized by discontinuities or discontinuous derivatives.
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
695