Stainless-Steel Column for Robust, High-Temperature Microchip Gas Chromatography
Abhijit Ghosh1,2, Austin R Foster2, Jacob C Johnson3
1Department of Chemistry and Biochemistry , Brigham Young University , Provo , Utah 84602 , United States.
Abstract:
This paper reports the first results of a robust, high-performance, stainless-steel microchip gas-chromatography (GC) column that is capable of analyzing complex real-world mixtures as well as operating at very high temperatures. Using a serpentine design, a 10 m column with an approximately semicircular cross-section with a 52 μm hydraulic diameter ( Dh) was produced in a 17 × 6.3 × 0.1 cm rectangular steel chip. The channels were produced using a multilayer-chemical-etch and diffusion-bonding process, and metal nuts were brazed onto the inlet and outlet ports allowing for column interfacing with ferrules and fused silica capillary tubing. After deactivating the metal surface, channels were statically coated with a ≈0.1 μm layer of 5% phenyl-1% vinyl-methylpolysiloxane (SE-54) stationary phase and cross-linked with dicumyl peroxide. By using n-tridecane ( n-C13) as a test analyte with a retention factor ( k) of 5, a total of 44 500 plates (≈4500 plates per meter) was obtained isothermally at 120 °C. The column was thermally stable to at least 350 °C, and rapid temperature programming (35 °C/min) was demonstrated for the boiling-point range from n-C5 to n-C44 (ASTM D2887 simulated-distillation standard). The column was also tested for separation of two complex mixtures: gasoline headspace and kerosene. These initial experiments demonstrate that the planar stainless-steel column with proper interfacing can be a viable alternative platform for portable, robust microchip GC that is capable of high-temperature operation for low-volatility-compound analysis.
More Related Videos
07:00Failure of Cleaning Verification in Pharmaceutical Industry Due to Uncleanliness of Stainless Steel Surface
Published on: August 11, 2017
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...