Related Experiment Video
Updated: Feb 1, 2026

Author Spotlight: Advancing Rapid Detection of Respiratory Pathogens Using Microfluidic Chip
Published on: March 29, 2024
Loop-mediated isothermal amplification-based detection of typhoid fever on an automated Genie II Mk2 system - A
Hagen Frickmann1, Dorothea Franziska Wiemer2, Lars Wassill3
1Department of Microbiology and Hospital Hygiene, Bundeswehr Hospital Hamburg, Bernhard-Nocht-Str. 74, 20359, Hamburg, Germany; Institute for Medical Microbiology, Virology and Hygiene, University Medicine Rostock, Schillingallee 70, 18057, Rostock, Germany.
Abstract:
Typhoid fever, caused by the bacterium Salmonella enterica subsp. enterica serovar Typhi, is an important cause of blood stream infections in the tropics, for which easy-to-apply molecular diagnostic approaches are desirable. The diagnostic performance of a newly introduced and a previously described loop-mediated isothermal amplification (LAMP) approach using different primer sets on a Genie II Mk2 device for the identification of Salmonella enterica ssp. enterica ser. Typhi was evaluated with well-characterized residual materials from the tropics in a case control-based approach. After in-vitro confirmation of binding characteristics of both LAMP primer sets with culture isolates (n = 112), sensitivity and specificity were 100% for the newly designed new LAMP primer set 1 with incubated blood culture materials, while specificity was reduced to 97.1% for primer set 2. For 170 EDTA blood samples, sensitivity and specificity were 10% and 98.3% for primer set 1 as well as 38.0% and 83.3% for primer set 2, respectively; qPCR from EDTA blood did not score much better with 10% sensitivity and 100% specificity. LAMP using a Genie II Mk2 device is suitable for the identification of Salmonella enterica spp. enterica ser. Typhi from incubated blood culture materials. Sensitivity and specificity were insufficient for diagnosis directly from EDTA blood samples but LAMP showed similar sensitivity as qPCR.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Types of Fever
Here are the different types of fever:
Patterns of Fever
Base Excision Repair
The first step of...
Isothermal Processes
An ideal gas can also undergo isothermal expansion or compression.
For example, consider 1 mole of an ideal gas inside an isolated cylinder at initial volume V...