Subcutaneous spacer injection to reduce skin toxicity in breast brachytherapy: A pilot study on mastectomy specimens
Gerson M Struik1, Jean-Philippe Pignol2, Inger-Karine Kolkman-Deurloo3
1Department of Surgery, Franciscus Gasthuis and Vlietland, Rotterdam, The Netherlands; Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam, The Netherlands.
Purpose:
Accelerated partial breast irradiation is a treatment option for selected patients with early-stage breast cancer. Some accelerated partial breast irradiation techniques lead to skin toxicity with the skin dose as a main risk factor. Biodegradable spacers are effective and safe in prostate brachytherapy to protect the rectum. We hypothesize that a subcutaneous spacer injection reduces the skin dose in breast brachytherapy.
Methods And Materials:
Ultrasound-guided spacer injections, either hyaluronic acid (HA) or iodined polyethylene glycol (PEG), were performed on fresh mastectomy specimens. Success was defined as a spacer thickness of ≥5 mm in the high-dose skin area. Usability was scored using the system usability scale. Pre and postinjection CT scans were used to generate low-dose-rate seed brachytherapy treatment plans after defining a clinical target volume. Maximum dose to small skin volumes (D0.2cc) and existence of hotspots (isodose ≥90% on 1 cm2 of skin) were calculated as skin toxicity indicators.
Results:
We collected 22 mastectomy specimens; half had HA and half had PEG injection. Intervention success was 100% for HA and 90.9% for PEG (p = NS). Hydrodissection was feasible in 81.8% with HA and 63.6% with PEG. Median system usability scale score was 97.5 for HA and 82.5 for PEG (p < 0.001). Mean D0.2cc was 80.8 Gy without spacer and 53.7 Gy with spacer (p < 0.001). Skin hotspots were present in 40.9% without spacer but none with spacer (p < 0.001).
Conclusions:
A spacer injection in mastectomy specimens is feasible. An extra 5 mm space is always achieved, thereby potentially reducing the skin dose dramatically in low-dose-rate seed breast brachytherapy.
More Related Videos
05:05Generating a Murine Orthotopic Metastatic Breast Cancer Model and Performing Murine Radical Mastectomy
Published on: November 29, 2018
06:42Optimization of Breast Biopsy and Mastectomy Sample Collection Procedures for Biobanking, Personalized Medicine, and Research Applications
Published on: September 2, 2025
Related Concept Videos
Pilot and Numeric Relaying
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Adaptations that Reduce Water Loss
Skin Cancer
Basal Cell Carcinoma (BCC): BCC is the most common type of skin cancer, accounting for about 80% of cases. It typically develops in...